Covers method of test for determination of carbon dioxide content of building lime.
Details:
The system consists of a U tube A with anhydrous granulated calcium chloride and another U tube B with soda asbestos, funnel C with a glass stopcock S and a bent inlet glass tube is used to introduce hydrochloric acid into the generating flask D.
Condenser E condenses most of the water and hydrochloric acid. The U tube F contains zinc pallets to react with residual acid, if any acid to absorb moisture. Bubbler G contains concentrated Sulphuric. The U tube Hr contains pumice stone, impregnated with anhydrous copper Sulphate to remove traces of hydrogen Sulphide.
Pumice stone is prepared by crushing it to approximately 5 mm size, shifting it free from dust and then transferring 60 g of it to a casserole, it is then covered with a concentrated solution of 30 to 35 g of copper Sulphate and then evaporated to dryness while stirring constantly.